Rig Name: 
Well: 
Date: 
SHIVGANGA DRILLERS LIMITED
HAZARD HUNT
DERRICK
Inspector Name: 
Project: 
Sign: 
This checklist has to be filled by SGDPL Drilling Superintendent or Rig Manager only SGD/QHSE/F/1.36
S.No Equipment Check List Task Compl.
Yes/No
Closing
Date
Description of non compliance or defect Priority
C, M, L
1 Derrick Is there any loose equipment in the derrick ?
2 Derrick Is the derrick clean and free from mud, dirt and rust ?
3 Derrick Is the crown free from excess grease ?
4 Derrick Is bumper timber block secured. Check that the crown bumper timber is in good condition.
5 Derrick Is the red aviation light fitted and working ?
6 Derrick Are all of the derrick lights secured with safety cable and working properly?
7 Derrick All pipe finger snubbed and secured in place.
8 Derrick Is stand pipe secured in place ?
9 Derrick Is mud hose secured at both ends?
10 Derrick Do all swivel sheaves have safety cables ?
11 Derrick Do all shackles have a safety pin or 4 part shackles?
12 Derrick Are there any bent members ?
13 Derrick Are there any missing members ?
14 Derrick Can the ladder be easily reached from the drill floor ?
15 Derrick Is the ladder in good condition ?
16 Derrick Is there wraparound ladder case (cage) ? Is it in good condition ?
17 Derrick Are there any broken welds ?
18 Derrick Is there a climbing belt available at doghouse which is certified and tested?
19 Derrick Is the anti-fall device fitted to the climbing belt ? Certification date?
20 Derrick Escape buggy/TEED installed & accessible, soft material at landing point ?
21 Derrick Check condition of derrick man belts - lanyards with shock absorber?
22 Derrick Is there a place to stand at the monkey board and crown when you take it off ? / standing platform
23 Derrick Ensure a grease system is available for crown sheaves.
24 Derrick Condition of tong counterweight assembly, secured & no loose object connected.
25 Derrick Wiring/electrical fixtures - condition (no loose wires)
26 Derrick Ensure crown platform is surrounded with toe board
27 Derrick Are jumper bars installed to avoid the cable jumping of the sheaves ?
28 Derrick Do all pulleys have SWL stamped? And secured ?
29 Derrick Do all hang off pad eyes have valid certification and enrolled in lifting register.
Critical (C): requires immediate action as it may lead to equipment malfunction and / or damage resulting in serious operational implications and or possible harm to environment, injury or loss of life.
Major (M): may lead to equipment malfunction resulting in significant damage to the equipment / item, which could subsequently have operational or safety related ramifications.
Low (L): May contribute to equipment / Item malfunction that has consequential implications and does not fail in to the above categories.