Rig Name:
Well:
Date:
|
SHIVGANGA DRILLERS LIMITED
HAZARD HUNT
DERRICK |
Inspector Name:
Project:
Sign:
|
| This checklist has to be filled by SGDPL Drilling Superintendent or Rig Manager only | SGD/QHSE/F/1.36 |
| S.No | Equipment | Check List Task | Compl. Yes/No |
Closing Date |
Description of non compliance or defect | Priority C, M, L |
|---|---|---|---|---|---|---|
| 1 | Derrick | Is there any loose equipment in the derrick ? | ||||
| 2 | Derrick | Is the derrick clean and free from mud, dirt and rust ? | ||||
| 3 | Derrick | Is the crown free from excess grease ? | ||||
| 4 | Derrick | Is bumper timber block secured. Check that the crown bumper timber is in good condition. | ||||
| 5 | Derrick | Is the red aviation light fitted and working ? | ||||
| 6 | Derrick | Are all of the derrick lights secured with safety cable and working properly? | ||||
| 7 | Derrick | All pipe finger snubbed and secured in place. | ||||
| 8 | Derrick | Is stand pipe secured in place ? | ||||
| 9 | Derrick | Is mud hose secured at both ends? | ||||
| 10 | Derrick | Do all swivel sheaves have safety cables ? | ||||
| 11 | Derrick | Do all shackles have a safety pin or 4 part shackles? | ||||
| 12 | Derrick | Are there any bent members ? | ||||
| 13 | Derrick | Are there any missing members ? | ||||
| 14 | Derrick | Can the ladder be easily reached from the drill floor ? | ||||
| 15 | Derrick | Is the ladder in good condition ? | ||||
| 16 | Derrick | Is there wraparound ladder case (cage) ? Is it in good condition ? | ||||
| 17 | Derrick | Are there any broken welds ? | ||||
| 18 | Derrick | Is there a climbing belt available at doghouse which is certified and tested? | ||||
| 19 | Derrick | Is the anti-fall device fitted to the climbing belt ? Certification date? | ||||
| 20 | Derrick | Escape buggy/TEED installed & accessible, soft material at landing point ? | ||||
| 21 | Derrick | Check condition of derrick man belts - lanyards with shock absorber? | ||||
| 22 | Derrick | Is there a place to stand at the monkey board and crown when you take it off ? / standing platform | ||||
| 23 | Derrick | Ensure a grease system is available for crown sheaves. | ||||
| 24 | Derrick | Condition of tong counterweight assembly, secured & no loose object connected. | ||||
| 25 | Derrick | Wiring/electrical fixtures - condition (no loose wires) | ||||
| 26 | Derrick | Ensure crown platform is surrounded with toe board | ||||
| 27 | Derrick | Are jumper bars installed to avoid the cable jumping of the sheaves ? | ||||
| 28 | Derrick | Do all pulleys have SWL stamped? And secured ? | ||||
| 29 | Derrick | Do all hang off pad eyes have valid certification and enrolled in lifting register. |