SHIVGANGA DRILLERS LIMITED
PRE-SPUD INSPECTION CHECKLIST
Installation Name/ Well No:
Name of Contractor:
Inspected By:
Date of Inspection: {InspectionDate}
S.No. Area of concerned Status Remarks
WELL SITE LAYOUT PLAN
1 Is security room available at well site?
2 Is Fencing installed along with entry gate to avoid unauthorized person entry into well site and its inspection record maintained?
3 Is Toilet with water facility available at site and cleanliness maintained?
4 Is dedicated parking area provided to accommodate vehicles while drilling activity on well site ongoing?
5 Is well site emergency exit plan with exit route making displayed and communicated to crew?
6 Is adequate safety signages displayed at site?
WASTE MANAGEMENT
7 Is DG set stack emission recorded and reports available?
8 Is hazardous waste generated such as used oil, batteries, oil containing cotton, empty paint and thinner containers etc.
9 Is medical waste management system implemented?
10 Is kitchen and food waste segregation and disposal system implemented?
SAFETY EQUIPMENT AND WARNING SIGNS
11 Appropriate warning and safety signs displayed
12 Qualified first- aiders & Fire Fighters available in each crew
13 First aid box available with adequate Medicine.
14 Emergency Eye Wash Station Installed
15 Lighting adequate & properly protected
16 Fire extinguishers charged, mounted, tagged, sealed (monthly inspection and annual maintenance)
17 High-pressure lines secured/anchored
18 MSDS are available for all required chemical substances on site ( Grease, paint, thinner etc)
19 Portable gas detector is operational and alarm is functional.
20 Emergency Contact Numbers & Standing Order for emergency control displayed.
21 Emergency Siren placed.
PERSONAL PROTECTIVE EQUIPMENT
22 All Personal wear Hard Hat and steel toe shoes worn
23 All Personal wear safety glasses.
24 Enough number of gloves available
25 All personal ware protecting clothing
26 Hearing Protection available where as required
27 Retractable Fall Arrester/ Safety line installed on mast.
28 Full Body Harness belt available & inspected by DIC
PIPE RACK AREA
29 Pipe rack level, stable & in good condition
30 Ends pinned & layers chocked to avoid rolling of stack
31 Adequate Lighting available
SUB STRUCTURE/CELLAR
32 Working platform installed and assembly pins in place & secured with keepers.
33 Adequate lighting; guarded; explosion-proof
34 Cellar area free of debris
35 Fire extinguisher placed in area
36 General Housekeeping conducted
MECHANICAL SAFETY
37 No missing bolts in machine and rotating equipment; all bolts tight & secure
38 Hydraulic and mechanical Control lines in good condition; no leaks
39 All rotating parts are protected and guarded.
40 All controls labeled; gauges working; hydraulic lines protected from mechanical hazards
41 Mechanical controls labeled & functioning properly
42 Adequate lighting provided on Machinery control area
STORAGE AREAS
43 Flammable liquids stored properly & labeled
44 Fire extinguishers provided
45 "No Smoking" signs posted
46 Items prevented from falling--toe plates, cages, otherwise secured
47 Trash containers; covered for oil-saturated rags
48 Combustibles away from light fixtures
49 Paint & paint thinner containers closed
DOCUMENTS AND RECORD KEEPING
50 ToolBox talk conducted and records maintained at site.
51 Mud pump pressure relief valve inspection conducted and record maintain at site.
52 Crown O Matic device function tested and record maintain at site.
53 Casing Line inspection record maintained at site
54 Lifting gear inspection register (Sling & D Shackles) updated and available at site
55 Hydra Inspection carried out and non-compliance recorded
56 Legal Compliance register (Based on OMR 2017 requirement) updated and maintained at site?
57 Observation and compliance report (CAR) available at site.
DG SET / GENERATOR
58 ”High Voltage” signs visible
59 Hearing protection available & signs visible
60 Fire extinguishers (CO2 type) mounted
61 All switches and electrical controls labeled
62 Wiring receptacles & lighting in good order
63 Switches & connector boxes have covers in place
64 All moving machinery properly guarded
65 General housekeeping; no oil on floor and combustibles contained or eliminated
MUD PUMP AREA
66 Lines all secured
67 Pop valve pin & cover in place
68 Hoses safety chained with clamp
69 All fitting of suction hose secured with two clips
70 Water suction hose with foot valve in good condition
71 Water returning from well goes to waste pit through channel
FLOORS, STAIRS & HANDRAILS
72 Working platform, carrier gratings & railing are fixed & secured by support.
73 Carrier Gratings & railings all in Place
74 Railings & Toe boards All in Place
75 Stairs Level, Clear, Clean & Secure with handrails
76 Fire extinguisher in place
77 Openings in floor properly guarded or covered
ELECTRICAL SAFETY
78 All electrical instruments, connections secured with adequate earthing points.
79 Lighting arrester installed and earthed properly.
80 Electrical System & accommodation/ office bunk insulations checked by electrician found OK.
FIRE FIGHTING AND FIRST AID FACILITY
81 Is fire-fighting equipment as fire pumps, water monitor, hydrant and fire hoses, fire nozzles etc. inspected and fit for purpose?
82 Is fire-fighting crew available in both the shifts?
83 Is adequate first aid provision with availability of paramedic ensured at site?
84 Is spill kit available at site?
85 Is Emergency response plan with details of emergency contingency scenarios captured in with response actions?
Remarks / Comments
CHIEF MECHANIC
CHIEF ELECTRICIAN
TOOL PUSHER
QHSE OFFICER
COMPANY MAN